2-15. COMPARTMENT CONTROL MODULE - MAINTENANCE INSTRUCTIONS (Cont).
ACTION
ITEM
LOCATION
REMOVAL/INSTALLATION
REMOVAL
1. Disassemble CCM (p 2-171).
2. Remove screw (1) and washer (2).
3. Pinch ears of clamps (3 and 4) and pull tubes from
pressure switch (5).
4. Carefully remove connectors (6) from pressure
switch (5).
INSTALLATION
1. Connect pressure switch (5) (tap marked LOW) to
tube (7).
2. Connect pressure switch (5) (tap marked HIGH) to
tube (8).
3. Install hose clamps (3 and 4) and electrical con-
nectors (6).
4. Reassemble CCM (p 2-171).