TM 3-4240-284-30&P
2-15. COMPARTMENT CONTROL MODULE - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMOVAL/lNSTALLATION
REMOVAL
Panel
Printed circuit assembly
(auxiliary switching)
2. Remove two screws (1), nuts (2), and washers (3)
3. Unsolder wires and remove auxiliary switching
printed circuit assembly (4).
CAUTION
Apply needle-nose pliers to the leads of the
diodes connected between terminals 1 and
2, 3 and 8, and 7 and 8 to form a heat sink
done to prevent heat damage to the diodes.
Use care to apply only enough heat as
necessary to form a good solder joint. This
applies to all terminals.
INSTALLATION
1., Connect and solder wires to auxiliary switching
2. Place auxiliary switching printed circuit assembly (4)
on bracket (5) and attach using screws (1),
washers (3), cable bracket (6), and nuts (2).
REMOVAL/INSTALLATION
REMOVAL
Housing
Flasher
2. Unsolder wires from flasher (1).
3. Remove two screws (2), nuts (3), and washers (4).
4. Remove flasher (1).
INSTALLATION
1. Install flasher(1) using two screws (2), washers (4),
and nuts (3).
2-175
--