TM 3-4240-284-30&P
2-15. COMPARTMENT CONTROL MODULE - MAINTENANCE INSTRUCTIONS (Cont).
ACTION
ITEM
LOCATION
REMOVAL
Pressure transducer
Housing
2. Remove connector (1) from pressure transducer (2).
3. Pull tubing (3) from pressure transducer (2).
4. Remove two screws (4) and remove pressure trans-
ducer (2).
REPAIR
Fabricate replacement tubing (3) from
Nonmetallic tubing
NSN 9330-01-073-1011 stock. Cut to same length as
tubing being replaced.
INSTALLATION
1. Install pressure transducer (2) using two screws (4).
Pressure transducer
2. Connect tubing (3) to presure transducer (2).
CAUTION
3. Connect connector (1) to connector (5).
When installing rub-
ber tubes, be sure that
the tube from the
pressure switch is
connected to the hose
connector marked LOW
on the pressure
transducer and that
the other tube is con-
nected to the hose
connector marked HIGH
on the pressure
transducer.
2-173