TM 3-4240-284-20&P
LOCATION
ITEM
ACTION
INSPECTION/REPAIR
NOTE
Top and bottom
M10 Protective
Entrance
shells
Two technicians are needed for this procedure:
one on theinsideof the entrance and one on the
outside.
Lay erected entrance on its side with door up.
Remove screws (1), pads (2), and retainer
assemblies (3).
Examine top (4) and bottom (5) shells for cracks, par-
ticularly in the area of A.
Change 1 2-62.1