M10 PROTECTIVE ENTRANCE - MAINTENANCE INSTRUCTIONS. - Continued
M10 PROTECTIVE ENTRANCE - MAINTENANCE INSTRUCTIONS. - Continued

Collective Protection Equipment, Fire Direction System, Artillery, \(Tacfire\) An/Gsg-10\(V\), M262
Page Navigation
  63    64    65    66    67  68  69    70    71    72    73  
img
. .
TM 3-4240-284-20&P
2-11. M10 PROTECTIVE ENTRANCE - MAINTENANCE INSTRUCTIONS (CONT).
ACTION
ITEM
LOCATION
DISASSEMBLY
Unscrew nut (1). Remove washer (2), screw (3), support
Dust and moisture seal
cable (4), and washer (5) from rubber cap (6).
protective cap
Unscrew adjustment screw on hose clamp (7) and
remove from rubber cap (6).
REPAIR
Fabricate support cable (fig E-1, app E).
Support cable
REASSEMBLY
Install hose clamp (7) in groove in rubber cap (6). Turn
Dust and moisture seal
adjustment screw just enough to keep clamp in place.
protective cap
Secure support cable (4) to rubber cap (6) with screw
(3), washer (5), washer (2), and nut (1).
2-60