TM 3-4240-284-20&P
Section VI. MAINTENANCE PROCEDURES FOR M10 PROTECTIVE ENTRANCE
2-10. GENERAL. These instructions are for use by
organizational maintenance personnel. They
apply to:
M10 Protective entrance
Protective entrance control module
2-11. M10 PROTECTIVE ENTRANCE - MAINTENANCE INSTRUCTIONS.
This task covers:
c. Removal
a. Replacement
g. Painting
e. Disassembly
h. Inspection/Repair
f. Reassembly
b. Repair
d. Installation
INITIAL SETUP
References
Tools
General Mechanics Tool Kit
TM 11-7440-294-14 (to be published)
SC 5180-90-CL-N26
Personnel Required: 2
Portable electric drill NSN 5130-00-889-8994
Twist drill NSN 5133-00-227-9650
ACTION
ITEM
LOCATION
REPLACEMENT
Refer to TM 11-7440-294-14 for protective entrance
Ml O Protective entrance
TACFIRE
replacement instructions.
REPAIR
Repair tears or slits:
M10 Protective Entrance
Impermeable wall fabric
Clean damaged area using rags (Item 6, app D) and
(PE)
dry-cleaning solvent (item 4, app D).
Cut a piece of tape (item 7, app D) about four inches
longer than the tear or slit. position tape over the tear
.
or slit and press firmly in place.
Apply tape to the inside of the protective entrant"
impermeable fabric wall. If necessary for added
strength, crossed strips of tape may be used
2-56 Change 1