ITEM
ACTION
LOCATION
REMOVAL (CONT)
Remove screws (9), aluminum washer (10), and
M56 Gas-Particulate Filter
Particulate and
washer (11).
gas filters
Unit
Pull access cover (6) from filter housing (8).
Pull gas filter (12) from filter housing (8).
Filter Housing Inner Cover
Replace access cover gasket (13) on filter housing, or
Gaskets
gasket (14) on inner cover (5) if unserviceable.
a. Remove gasket from groove.
b. Clean groove using solvent (item 4, app D).
c. Apply cement (item 1, app D) to groove.
d. Install gasket.