TM 3-4240-286-20&P
2-14. M 5 6 GAS-PARTICULATE FILTER UNIT - M AI NTENANCE INSTRUCTIONS (CONT).
ACTION
ITEM
LOCATION
INSTALLATION
Push tube coupling nuts (6 and 8) with sleeves on red
M56 Gas-Particulate Filter
Red tubing (nonmetallic)
tube (10). See detail A.
Unit
Push one end of tube (10) into connector (7) and one
TUBE
end into connector (9). RED dot on power distribution
COUPLING
unit indicates connector (9).
NUT
Push tube coupling nut (6) with sleeve onto connector
SLEEVE
(7) and handtighten.
TUBE
Push tube coupling nut (8) with sleeve onto connector
(9) and handtighten.
Push tube coupling nut (3) with sleeve onto connector
(4) and handtighten.
DETAIL A
Push tube coupling nuts (1 and 3) with sleeves on green
Green tubing
tube (5). See detail A.
(nonmetallic)
Push one end of tube (5) into connector(2) and one end
into connector (4). GREEN dot on power distribution unit
indicates connector (4).
Push tube coupling nut (1) with sleeve onto connector
(2) and handtighten.
Push tube coupling nut (1) with sleeve onto connector
(2) and handtighten.
2-76