M56 GAS- PARTICULATE FILTER UNIT - MAINTENANCE INSTRUCTIONS. - Continued
M56 GAS- PARTICULATE FILTER UNIT - MAINTENANCE INSTRUCTIONS. - Continued

Collective Protection Equipment, Air Defense Command And Control System, An/Tsq-73, M263
Page Navigation
  79    80    81    82    83  84  85    86    87    88    89  
img
TM 3-4240-286-20&P
2-14. M 5 6 GAS-PARTICULATE FILTER UNIT - M AI NTENANCE INSTRUCTIONS (CONT).
ACTION
ITEM
LOCATION
INSTALLATION
Push tube coupling nuts (6 and 8) with sleeves on red
M56 Gas-Particulate Filter
Red tubing (nonmetallic)
tube (10). See detail A.
Unit/Power Distribution
Unit
Push one end of tube (10) into connector (7) and one
TUBE
end into connector (9). RED dot on power distribution
COUPLING
unit indicates connector (9).
NUT
Push tube coupling nut (6) with sleeve onto connector
SLEEVE
(7) and handtighten.
TUBE
Push tube coupling nut (8) with sleeve onto connector
(9) and handtighten.
Push tube coupling nut (3) with sleeve onto connector
(4) and handtighten.
DETAIL A
Push tube coupling nuts (1 and 3) with sleeves on green
Green tubing
tube (5). See detail A.
(nonmetallic)
Push one end of tube (5) into connector(2) and one end
into connector (4). GREEN dot on power distribution unit
indicates connector (4).
Push tube coupling nut (1) with sleeve onto connector
(2) and handtighten.
Push tube coupling nut (1) with sleeve onto connector
(2)  and  handtighten.
2-76