TM 3-4240-286-20&P
2-14. M 56 GAS-PARTICULATE FILTER UNIT - M AINTENANCE INSTRUCTIONS (CONT).
ACTION
ITEM
LOCATION
REMOVAL
Lift edge of plate with a sharp tool.
Identification plate
M56 Gas-Particulate Filter
Unit
Pull plate completely off the mounting surface.
INSTALLATION
Thoroughly clean mounting surface with dry-cleaning
solvent (item 4, app D). Mounting surface must be free
foreign matter.
Activate the back of the mounting plate with dry-
Mount the plate (1) and apply pressure to the
plate surface.
Spray or brush plate with aliphatic polyurethane coating
PAINTING
Touch-up painting is authorized.
Filter housing compart-
ment control module and
Thoroughly clean the surfaces to be repainted. Use rags
power distribution unit
Paint surfaces with one coat of primer (item 5, app D).
Paint primed surfaces with aliphatic polyurethane coat-
NOTE
Refer to TM 43-0139 for painting instruc-
tions for field use.
2-78