• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
M56 GAS- PARTICULATE FILTER UNIT - MAINTENANCE INSTRUCTIONS. - Continued
M56 GAS- PARTICULATE FILTER UNIT - MAINTENANCE INSTRUCTIONS. - Continued

Collective Protection Equipment, Air Defense Command And Control System, An/Tsq-73, M263
Page Navigation
  77    78    79    80    81  82  83    84    85    86    87  
img
TM 3-4240-286-20&P
2-14. M 56 GAS-PARTICULATE FILTER UNIT - M AINTENANCE INSTRUCTIONS (CONT).
ACTION
LOCATION
ITEM
REASSEMBLY
Insert screw (14) in washer (15), loop of support cable
Dust and moisture seal
(9) and hole in rubber cap (10).
Install washer (13) and nut (12). Tighten securely.
Install hose clamp (16) in groove in rubber cap (10).
INSTALLATION
Insert screw (8) in washer (11), loop of support cable(9),
Dust and moisture seal
M56 Gas-Particulate Filter
and hole in inlet tee (3).
protective cap
Unit
Install washer (7) and nut (6). Tighten securely.
Place airduct hose (2) on inlet tee. Tighten hose clamp
adjusting screw (1).
Install airduct hose (5) on airflow valve (17). Tighten
hose clamp adjusting screw (4).
2-74