PROTECTIVE ENTRANCE CONTROL MODULE - MAINTENANCE INSTRUCTIONS. - Continued
M56 GAS-PARTICULATE FILTER UNIT - MAINTENANCE INSTRUCTIONS. - Continued

Collective Protection Equipment, Fire Direction System, Artillery, \(Tacfire\) An/Gsg-10\(V\), M262
Page Navigation
  73    74    75    76    77  78  79    80    81    82    83  
img
TM 3-4240-284-20&P
Section VII. MAINTENANCE PROCEDURES FOR
M56 GAS-PARTICULATE FILTER UNIT
2-13. GENERAL. These instructions are for use by
organizational maintenance personnel. They
apply to:
M56 Gas-particulate filter unit
Main fan
Airflow valve
Power distribution unit
Compartment control module
2-14. M56 GAS-PARTICULATE FILTER UNIT - MAINTENANCE INSTRUCTIONS.
This task covers:
e. Reassembly
a.
Replacement
f. Repair
b.
Removal
c.
Installation
g. Painting
d.
Disassembly
INITIAL SETUP
Tools
References
General Mechanics Tool Kit
TM 11-7440-294-14 (to be published)
SC 5180-90-CL-N26
Torque wrench 0-500 inch-pounds
General Safety Instructions
The unit commander or senior officer in charge of maintenance personnel assigned to remove and dispose of the
contaminated gas and particulate filters must prescribe the necessary protective clothing (TM 10-277) to be worn
during this operation. He must also prescribe the necessary safety measures to be followed including the
decontamination operation (TM 3-220) that must be performed before the new filters are installed.
ACTION
ITEM
LOCATION
REPLACEMENT
Refer to TM 11-7440-294-14 for M58 gas-particulate
TACFIRE
M56 Gas-particulate filter
filter unit removal and installation instuctions.
unit
2-68