TM 3-4240-284-20&P
LOCATION
ITEM
ACTION
REMOVAL
M56 Gas-Particulate Filter
Dust and moisture seal
Unscrew hose clamp adjusting screw (1) and remove
Unit
protective cap
airduct hose (2) from inlet tee (3).
Unscrew hose clamp adjusting screw (4) and remove
shelter airduct hose (5).
Remove nut (6) and washer (7) from screw (8).
Remove screw (8) from inlet tee (3), loop of support
cable (9) with dust and moisture seal protective cap
(10), and washer (11).
DISASSEMBLY
Remove nut (12) and washer (13) from screw (14).
Remove screw (14) from rubber cap (10), loop of sup-
port cable (9), and washer (15).
Remove hose clamp (16) from rubber cap (10).
REPAIR
Support cable
Fabricate support cable (fig E-1, app E).
2-73