2-14. M56 GAS-PARTICULATE FILTER UNIT - MAINTENANCE lNSTRUCTIONS (CONT).
ACTION
ITEM
LOCATION
REASSEMBLY
Insert screw (14) in washer (1 5), loop of support cable
Dust and moisture seal
(9) and hole in rubber cap (10).
Install washer (13) and nut (12). Tighten securely.
Install hose clamp (16) in groove in rubber cap (10).
INSTALLATION
Insert screw (8) in washer (11), Ioop of supportable (9),
Dust and moisture seal
M56 Gas-Particulate Filter
protective cap
and hole in inlet tee (3).
Unit
Install washer (7) and nut (6). Tighten securely.
Place airduct hose (2) on inlet tee. Tighten hose clamp
adjusting screw (1).
Install airduct hose (5) on airflow valve (17). Tighten
hose clamp adjusting screw (4).
2-74