Section III. ELECTRIC MOTOR INSTALLATION GROUP
the stand assembly. Four tapped holes are provided in
11. Description and Function
the stand assembly for the capscrews that fasten the
The electric motor (fig. 5) is described in TM 3-
blower mount to the stand assembly. Two holes in the
4240-241-12. The motor stand assembly is welded from
base of the stand assembly are provided for mounting
plate and sheet aluminum alloy. The motor is fastened
the stand assembly on the canister.
to the stand assembly with four capscrews, nuts and
12. Maintenance
installed under the mounting feet of the motor to raise
the motor power takeoff shaft in line with the blower
Direct support maintenance personnel
are
connection. The motor shaft extends through a hole in
authorized to replace the electric motor, motor
1
5.
Hex nut
1.
Capscrew
6.
Lockwasher
2.
Electric motor
7.
Male plug connector
3.
Spacer block
8.
Electric cable
4.
Motor stand assembly
Figure 5. Electric motor installation group.
AGO 8767A
9