CHAPTER 3 GENERAL SUPPORT MAINTENANCE INSTRUCTIONS
Section II. CANISTER GROUP

Ds, Gs, And Depot Maintenance Manual Filter Unit, Gas-Particulate, Ged, 300 Cfm, Abc-M6A1 And
Page Navigation
  5    6    7    8    9  10  11    12    13    14    15  
img
.
15
Capscrew
8 Left-hand blower casing
1
Blower gasket
16
Locking coupling tube
9 Machine screw
2
Blower mount
17
Locking coupling
10 Locking coupling adapter
3
Lockwasher
18
Drive screw
11 Gasket
4
Self-locking nut
19
Capscrew
12 Drive bushing
5
Right-hand blower casing
13 Flat washer
6
Screw
14 Lockwasher
7
Impeller
Figure 6. Blower assembly.
surfaces of blower casing and blower
(2) Weld cracks in blower casings.  Bolt or
mount. Be sure screws are flush or below
clamp blower casings to flat surface
surface of the blower casing to prevent
during  welding  operation  to  prevent
interface with the impeller (7) .
warping of casting. Grind welds on inside
of  blower  casings  to  allow  proper
(3) Place impeller (7) on shaft of gasoline
clearance for impeller. Grind or machine
engine or electric motor.
Be sure
mating surfaces of blower casings after
counterbore for washers in impeller (13
welding. Remove nicks and burrs with a
and 14) are facing outward toward end of
file and aluminum oxide abrasive cloth.
shaft.
(4) Insert drive bushing (12) on shaft so that
thin end fits between shaft and impeller
d. Assembly and Installation. (fig. 6). Assemble
(7).  Install capscrew (15), lockwasher
the blower and install on the shaft of the gasoline engine
(14), and flat washer (13).
Tighten
or electric motor as follows:
capscrew to force the drive bushing into
the impeller, locking it to the shaft.
(1) Install blower gasket (1) and fasten blower
(5) Coat mating surfaces of adapter (10) and
mount (2) to engine or motor stand
left-hand blower casing (8) with gasket
assembly with four capscrews (19) and
sealing compound.  Fasten adapter to
lockwasher (3).
blower casing with four screws (6).  Be
(2) Fasten right-hand blower casing (5) to
sure screws are flush or below surface of
blower mount (2) with four screws (6).
blower casing to prevent interference with
Use gasket sealing compound, type II,
impeller (7).
Specification  MIL-S-45180  on  mating
AGO 8757A