TM 3-4230-209-20&P
2-190
2-33. CONTROL BOX ASSEM BLY (CONT).
REMARKS
ACTION
LOCATION/lTEM
Control Box Assembly/
WARNING
Thermal relay (33)
Screw (34)
Make certain thermal relays are not installed in wrong
Band (35)
socket. Personnel injury and damage to equipment will
result.
Position thermal relay (33) in socket and aline pins. Press in fully.
Tighten screw (34) or snap latch until band (35) firmly holds thermal
relay (33). Repeat procedures for second thermal relay (33).
This task covers repair.
Materials/Parts
INITIAL SETUP
Electrical insulation tape (item 37, app D)
Tools and Special Tools
Equipment Condition
Automotive Maintenance and Repair Shop Equipment, Less Power
Assembled
(SC 4910-95-CL-A72 and SC 4910-95-CL-A74)
REMARKS
ACTION
LOCATION/lTEM
Fuel Hose Assembly/
Unit maintenance is authorized to tighten connections to stop
Insulation tape (1)
fuel leaks.
Start six inches from each end and tape full length of two hoses
in eight equally spaced areas with electrical insulation tape (1).