CONTROL BOX ASSEMBLY - Continued
CONTROL BOX ASSEMBLY - Continued

Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  204    205    206    207    208  209  210    211    212    213    214  
img
CAUTION
Do not bend or kink capillary tube. Any damage requires
replacement. Do not coil capillary tube in a coil less than 6
inches in diameter.
Remove two nuts (15) from rear of water temperature indicator ther-
Nuts (15)
mometer (16) and slide metal bracket (17) carefully back on the capillary
Water temperature
tube (18) without damaging it.
indicator
thermometer (16)
Insert end of capillary tube (18) through control box assembly (2) and
Metal bracket (17)
slightly angle metal bracket (17) so it will pass through the control box
Capillary tube (18)
assembly hole.
Position metal bracket (17) onto rear of water temperature indicator ther-
mometer (16) and secure with two nuts (15).
TM 3-4230-209-20&P
2-187