2-9. PERSONNEL SHOWER ASSEMBLY (CONT).
REMARKS
ACTION
LOCATION/lTEM
Disassemble upper rear support (1) by unscrewing coupling half with male
Personnel Shower Assembly/
threads (2), pipe plug (3), coupling half with female threads (4), and pipe
Upper Rear Support
(5) from pipe tee (6).
Remove dirt, trash, and rust. Clean with hot, soapy water then rinse with
Personnel Shower Assembly
clear water. Paint chipped and worn areas with polyurethane coating, as
necessary.
Replace authorized unserviceable parts. To replace pipe (5), see
Personnel Shower Assembly
figure E-4.
Apply antiseizing tape or sealing compound to all male
Reassemble by screwing pipe (5), coupling half with female threads (4),
Personnel Shower Assembly/
pipe plug (3), and coupling half with male threads (2) into pipe tee (6).
threads before reassembly.