TM 3-4240-286-20&P
Section VI. MAINTENANCE PROCEDURES FOR M12 PROTECTIVE ENTRANCE
2-10. GENERAL. These instructions are for use by
organizational maintenance personnel. They
apply to:
M12 Protective entrance
Protective entrance control module
2- 11. M12 PROTECTIVE ENTRANCE - MAINTENANCE INSTRUCTIONS.
This task covers:
g. Painting
c. Removal
a. Replacement
e. Disassembly
d. Installation
b. Repair
f. Reassembly
INITIAL SETUP
References
Tools
TM 9-1430-651-12
General Mechanics Tool Kit
SC 5180-90-CL-N26
ACTION
ITEM
LOCATION
REPLACEMENT
Refer to TM 9-1430-651-12 for protective entrance
M12 Protective entrance
AN/TSQ-73
replacement instructions.
REPAIR
Repair tears or slits:
Impermeable wall fabric
M12 Protective Entrance
Clean damaged area using rags (item 6, app D) and
(PE)
dry-cleaning solvent (item 4, app D).
Cut a piece of tape (item 7, app D) about four inches
longer than the tear or slit. Position tape over the tear
or slit and press firmly in place.
Apply tape to the inside of the protective entrance
impermeable fabric wall. If necessary for added
strength, crossed strips of tape may be used.
2-56