2-12. AIRFLOW VALVE - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMOVAL/INSTALLATION (Cont)
Airflow Valve
Motor with radio noise filter
5. Install screw (2), GRD 4 terminal lug (3), and nut (1).
6. Observing the wiring diagram on page 2-160, solder
the tagged wires (4 and 5) to lugs on FM radio noise
filter (6).
7. Bring cabling between motor (16) and FL2 radio
noise filter (6) together and install cable strap (7),
screw (9), and nut (8).
.
REMOVAL/INSTALLATION
REMOVAL
1. Cut and remove cable ties (1 thru 5) and separate the
Airflow Valve
Radio noise filter
wires.
.
2. Tag and unsolder one pair of wires (6) from FL1 radio
noise filter (8) negative () terminal.
3. Tag and unsolder one pair of wires (7) from FL1 radio
noise filter (8) positive (+) terminal.
4. Remove two screws (9) and nuts (10).
2-152