AIRFLOW VALVE - MAINTENANCE INSTRUCTIONS.
AIRFLOW VALVE - MAINTENANCE INSTRUCTIONS. - Continued

Collective Protection Equipment, Fire Direction System, Artillery, \(Tacfire\) An/Gsg-10\(V\), M262
Page Navigation
  152    153    154    155    156  157  158    159    160    161    162  
img
TM 3-4240-284-30&P
2-12. AIRFLOW VALVE - MAINTENANCE INSTRUCTIONS (Cont).
ITEM
LOCATION
ACTION
REMOVAL/INSTALLATION (Cont)
5. Loosen setscrew (12) and remove gear (13).
6. Remove four nuts (14) and screws (15).
7. Remove motor (16) and FL2 radio noise filter (6) as a
unit.
8. Remove screw (17), washer (18), and grounding
wire (19).
INSTALLATION
1.Install grounding wire (19) Cm motor (16) with washer
(18) and screw (17).
2. Install motor (16) in airflow valve (20) using four
screws (15) and nuts (14).
3. Install gear (13) on shaft of motor (16). Tighten
setscrew (12).
4. Install FL2 radio noise filter (6) and grounding
wire (19) in airflow valve (20) using screws (11) and
nuts (1 0).
2-151