2-12. AIRFLOW VALVE - MAINTENANCE INSTRUCTIONS.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Equipment Condition
Tools
Airflow valve removed from filter unit or airflow valve
Electronic Equipment Tool
removed from airflow valve and silencer.
Kit TK-105/G- (SC 5180-91-CL-R07)
NOTE
References
TB SIG 222
Perform all electrical connections in
accordance with wiring diagram on page
Troubleshooting References
2-160.
Refer to page 2-33.
ACTION
ITEM
LOCATION
REMOVAL/INSTALLATION
l
REMOVAL
1. Remove nut (1) and screw (2) from GRD 4 terminal
lug (3).
2. Tag and unsolder wires (4 and 5) from FL2 radio
noise fitter (6).
3. Cut cable strap (7). Remove nut (8), screw (9) and
cable strap (7).
4. Remove two nuts (10) and screws (11 ).
2-150