CONTROL PANEL ASSEMBLY. - Continued
CONTROL PANEL ASSEMBLY. - Continued

Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  130    131    132    133    134  135  136    137    138    139    140  
img
Control Panel Assembly/
Repair by replacing authorized components.
All components
Use epoxy primer and polyurethane coating to paint the
Metal surface
control panel assembly as needed (see TM 43-0139).
Cut and trim green tape to fit into the tachometer's 3800
Range mark on
to 3900 RPM range. Place on tachometer glass lens.
Tachometer
Control Panel Assembly/
NOTE
Tighten mounting hardware enough to keep gages from
rotating. Do not overtighten.
Install ammeter (1) into control panel (2) and
Ammeter (1)
fasten with bracket (3) and nuts (4). connect
Control paneI (2)
electrical leads (5).
Bracket (3)
Nuts (4)
Electrical leads (5)
Install circuit breaker (6) onto rear of control
Circuit breaker (6)
panel (2) and press boot assembly (7) onto
Boot assembly (7)
toggle of circuit breaker. Place switch
Switch shield (8)
shield (8) onto control panel (2), secure with
Lock washers (9)
lock washers (9) and machine screws (10).
Machine screws (10)
Connect electrical leads (11).
Electrical leads (11 )