2-26. CONTROL PANEL ASSEMBLY (CONT).
LOCATION/lTEM
ACTION
REMARKS
Control Panel Assembly/
Electrical leads (61 )
Disconnect electrical leads (61 ) from ammeter (62). remove nuts (63) and
Carefully tag and disconnect electrical leads (61 and
Ammeter (62)
bracket (64) and remove ammeter (62) from control panel (3).
65) for reassembly.
Nuts (63)
Bracket (64)
Electrical leads (65)
Disconnect electrical leads (65) from circuit breaker (66).
Circuit breaker (66)
Machine screws (67)
Remove machine screws (67), lock washers (68), switch shield (69), and
Lock washers (68)
boot assembly (70) from the front of control panel (3) and the circuit
Switch shield (69)
breaker (66) from the back of control panel (3).
Boot assembly (70)