TM 10-4330-236-13&P
4-32.
WATER DETECTION ADAPTER ASSEMBLY REPAIR - continued.
I
c.
Assembly.
(1) Apply sealant on threads and screw couplings (6 and 10) on adapter nipple (12).
(2) Install gasket (11) into coupling (10).
(3) Install dust plug (5) into coupling (10) and push cam handles (9) down to secure dust plug.
(4) Install gasket (8) in dust cap (4).
(5) Install dust cap (4) onto coupling (6) and push cam handles (7) down to secure dust cap.
(6) Attach split rings (2) to chains (3), dust plug (5). dust cap (4) and coupling (6).
(7) Apply sealant to threads on adapter nipple (12) and install probe (1) into the adapter nipple (12). Make sure the
bevel (13) on the sampling probe points toward the female coupling (10).
Figure 4-23. Water Detection Adapter Assembly Repair.
4-45