4-31. GROUND CABLE ASSEMBLY REPAIR
This task consists of:
a.
Disassembly
b.
Repair
c.
Assembly
INITIAL SET-UP:
Tools
General Safety Instructions
General Mechanics Tool Kit (Appendix B, Section
III, Item 1)
WARNINGS
·Do not smoke within 100 feet of filter-separator.
Materials/Parts
·Fuel is toxic to skin, eyes, and respiratory tract.
Cable (Appendix C, Section II)
·Wear safety goggles or glasses to protect your eyes.
Equipment Conditions
Filter-separator removed from system andtank
drain. Refer to para 2-6.
Air vent valve open. Refer to para 2-6.
Ground cable removed. Para 2-5.
Refer to figure 4-22.
a. Disassembly. Remove four alien screws (1) from two clips (2) and pull ends (3) of cable (4) from clips.
b. Repair. Replace defective components. Refer to Appendix G, Figure G- 1 for fabrication of cable.
c. Assembly.
WARNING
Wear safety goggles or glasses to protect your eyes from injury when cutting cable.
(1)
Cut six feet of cable (4). Refer to Appendix G, F
igure G-1.
(2)
Insert ends (3) of cable (4) into clips (2) and install alien screws (1) to secure ends in clips.
Figure 4-22. Ground Cable Repair.
4-43