AIRFLOW VALVE - MAINTENANCE INSTRUCTIONS.
AIRFLOW VALVE - MAINTENANCE INSTRUCTIONS. - Continued

Collective Protection Equipment, Fire Direction System, Artillery, \(Tacfire\) An/Gsg-10\(V\), M262
Page Navigation
  88    89    90    91    92  93  94    95    96    97    98  
img
. .
TM 3-4240-284-20&P
ACTION
ITEM
LOCATION
Remove nut (12) from screw (13). Remove screw (13)
Airflow Valve
Dust and moisture seal
from airflow valve, supportable (14), washer (15), sup
protective cap
port cable (16), and washer (17).
Remove nut (18) and washer (19) from screw (20).
Remove screw (20) from rubber cap (21), support cable
(22), and washer (23).
Remove hose damp (24) from rubber cap (21).
REPAIR
Fabricate support cable (fig E-1, app E).
Support cable
REASSEMBLY
Airflow Valve
Install screw (20) in washer (23), loop of support cable
Dust and moisture seal
(22), hole in rubber cap (21), washer, and nut (18).
protective
Tighten nut securely.
Install hose damp (24) in groove in rubber cap (21).
Do not tighten adjusting screw.
Install screw (13) in washer (17), loop of support cable
(16), washer (15), support cable (14), hole in airflow
valve, and nut (12). Tighten nut securely.