COMPARTMENT CONTROL MODULE - MAINTENANCE INSTRUCTIONS.
AIRFLOW VALVE AND SILENCER - MAINTENANCE INSTRUCTIONS.

Collective Protection Equipment, Fire Direction System, Artillery, \(Tacfire\) An/Gsg-10\(V\), M262
Page Navigation
  93    94    95    96    97  98  99    100    101    102    103  
img
TM 3-4240-284-20&P
2-18. COMPARTMENT CONTROL MODULE - MAINTENANCE INSTRUCTIONS (CONT).
ACTION
ITEM
LOCATION
REMOVAL
Using two screwdrivers, gently pry lens (1) module from
MASK lamp
Compartment Control
control panel (2).
Module
NOTE
Observe the location of the lamps in the
lens module. Lamps must be reinstalled in
the same sockets.
Pull lamps (3) from lens (1).
LOW PRESSURE lamp
Same as MASK lamp.
Same as MASK lamp.
OCCUPIED lamp
CHANGE FILTER lamp
Unscrew lens (4). Remove lamp (5).
INSTALLATION
MASK lamp
Insert lamps (3) into lens (1). Use the same lamp soc-
kets that lamps were removed from.
Insert lens (1) into control panel (2), as shown in detail A.
Press lens into panel until it snaps into place.
LOW PRESSURE lamp
Same as MASK lamp.
Same as MASK lamp.
OCCUPIED lamp
DETAIL
Insert lamp (5) into lens (4).
CHANGE FILTER lamp
Screw lens (4) into control panel (2).
2-88