2-16 AIRFLOW VALVE - MAINTENANCE INSTRUCTIONS.
d Reassembly
This task covers:
e. Installation
a. Removal
b. Disassembly
c. Repair
INITIAL SETUP
Tools
References
TM 11-7440-294-14 (to be published)
General Mechanics Tool Kit
SC 5180-90-CL-N26
ACTION
ITEM
LOCATION
REMOVAL
Set POWER switch (1) on compartment control module
Airflow valve
M56 Gas-Particulate Filter
to OFF.
Unit
Loosen hose damp adjusting screws (2) and remove
airduct hoses (3).
Disconnect electrical plug P15 (4) from airflow valve
connector J15 (5).
Remove nuts (6), screws (7), and washers (8).
Separate airflow valve (9) from fitter unit (10).
Replace airflow valve gasket (11) if unserviceable.
Remove gasket from flange on airflow valve.
Clean flange using dry-cleaning solvent (item 4,
app D).
Apply adhesive (item 1, app D) to flange.
Install gasket.
2-82