Replace authorized unserviceable parts. Replace rubber hose if it is less
Water Hose Assembly/
than 25 ft long or is leaking.
REASSEMBLY
Water Hose Assembly/
Slide two hose clamps (2) loosely onto the nonmetallic hose (1). Insert
Nonmetallic hose (1)
pipe to hose straight adapter (3) into nonmetallic hose (1). Push pipe to
Hose clamps (2)
hose straight adapter (3) all the way back until front edge of nonmetallic
Pipe to hose straight
hose (1) is against the hexagon nut area. Tighten hose clamps (2) accord-
adapter (3)
ing to page 2-77.
Wrap the external threads of pipe to hose straight adapter (3) with anti-
seizing tape or coat with sealing compound.
Screw quick disconnect coupling half (4) onto pipe to hose straight
Quick disconnect
adapter (3) and tighten. Install gasket (5) into quick disconnect coupling
coupling half (4)
half (4).
Gasket (5)
TM 3-4230-209-20&P