POSITIVE BATTERY CABLE.
PUMP UNIT SUBASSEMBLY. - Continued

Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  104    105    106    107    108  109  110    111    112    113    114  
img
. . . . . .
Fabricate cable (1) according figure E-6. Install terminal lugs (2) onto each
Cable (1)
end of cable (1) and crimp to secure.
Terminal lugs (2)
Position terminal (3) on end of terminal lug (2) and install bolt (4) through
Terminal (3)
Bolt (4)
both holes. Secure with nut (5).
Nut (5)
2-20. PUMP UNIT SUBASSEMBLY.
This task covers:
c. Reassembly
a. Disassembly
b. Repair
INITIAL SETUP
References
Tools and Special Tools
TM 43-0139
Automotive Maintenance and Repair Shop Equipment, Less Power
(SC 4910-95-CL-A72 and SC 4910-95-CL-A74)
Equipment Condition
Cover panels are removed.
Materials/Parts
Major components of the pump unit assembly are removed.
Antiseizing tape (item 35, app D)
See paragraph 2-12 for disassembly/reassembly procedures.
Chain (fig E-7)
Paint brush (item 6, app D)
Polyurethane coating (green) (item 28, app D)
TM 3-4230-209-20&P