PUMP UNIT. - Continued
PUMP UNIT. - Continued

Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  79    80    81    82    83  84  85    86    87    88    89  
img
TM 3-4230-209-20&P
2-62
2-12. PUMP UNIT (CONT).
REMARKS
ACTION
LOCATION/lTEM
Pump Unit/Control Panel
Make sure valve (3) is in open position when handle is
Insert locking sleeve (1) and sleeve extension (2) over the stem of ball
Locking sleeve (1)
installed in the center position. Valve will close when
valve (3) and secure with nut (4).
Sleeve extension (2)
handle (7) is moved to CLOSE.
Ball valve (3)
Nut (4)
Insert extension rod (5), aline its holes with holes in sleeve extension (2),
Extension rod (5)
and insert spring pin (6).
Spring pin (6)
Put handle (7), fiat washer (8), and hexagon self-locking nut (9) on the
Handle (7)
other end of extension rod (5). Tighten nut (9).
Flat washer (8)
Hexagon self-locking nut (9)