  74    75    76    77    78  79  80    81    82    83    84  
img
Pump Unit/Fuel Tank
Make sure the fuel in fuel tank (1) is drained into container. Clean fuel
Assembly and
tank (1) exterior with dry cleaning solvent.
Sediment Bowl
Loosen round nut (2) on the bottom of sediment bowl frame (3). Remove
Fuel tank (1)
glass sediment bowl (4) carefully, and dump the fuel into container used
Nut (2)
to drain the fuel tank. Empty fuel in accordance with approved mainte-
Frame (3)
nance practices. Reinstall glass sediment bowl (4) and tighten round
Bowl (4)
nut (2) until tight.
Wires (5)
Cap (6)
Inspect fuel tank (1) for leaks, broken welds, or other damage. Inspect for
Gaskets (7)
signs of corrosion inside the tank and clean the fuel tank if necessary. "
Inspect the electrical wires (5) attached to liquid quan-
tity transmitter for loose or damaged terminals.
Inspect fuel cap (6) to make sure it is tight.
Inspect to make sure fuel tank is mounted
securely. Check that polyurethane
foam gaskets (7) are not damaged.
Inspect fuel tank (1) for dents
chipped or damaged paint.