TM 11591522613
Table 4-2. Operator and Organizational Troubleshooting Procedures
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE MEASURES
1. POWER INDICATOR WILL NOT LIGHT
Step 1.
Check if POWER CIRCUIT BREAKER is set to ON; if
not:
Set to ON. If circuit breaker breaks again,
higher level of maintenance is required. Re-
Step 2.
Check security of input/output connectors.
Tighten loose connections.
Step 3.
If POWER CIRCUIT BREAKER is set ON and
POWER INDICATOR lamp does not light.
Turn dimmer cap counterclockwise to
brighten.
If lamp does not light, and is not defective,
higher level of maintenance is required.
44