TM 10-4330-230-12&P
c.
Fluid Lines. Look for wear, damage, and leaks. Make sure clamps and fittings are tight. Wet spots and
stains around a fitting or connector can mean a leak. If a leak comes from a loose connector, tighten it. If
something is broken or worn out, report it to unit maintenance.
d. Painting. Touch-up filter/separator as needed. Refer to TM 43-0139 for specific painting procedures.
Table 2-1. Operators Preventive Maintenance Checks and Services (PMCS).
NOTE
Within designated intervals, these checks are to be performed in the order listed.
B Before
D During
A After
Interval
Item
Equipment is Not
no.
B
D
A
Item to be Inspected
Procedure
Ready/Available If:
1
l
l
l
Filter/Separator and
Inspect filter/separator and skid for
Filter/separator leaks or
Skid
leaks and damaged or missing
parts are damaged or
parts.
missing
2
l
l
Sight Gage
Inspect for leaks, cracked or
Sight gage is broken or
broken glass.
leaking.
3
l
l
Pressure Vent Valve
Inspect pressure vent valve for
Pressure vent valve is
leaks and proper operation.
inoperable.
4
l
l
Water Drain Valve
Inspect water drain valve for leaks
Water drain valve leaks or
and proper operation
is inoperable.
5
l
l
Inlet and Outlet
Inspect inlet and outlet valves for
Inlet or outlet valves leak or
Valves
leaks and proper operation.
are inoperable.
2-5