TM 5-4330-263-13&P
0010 00
Figure 1. Sight Gauge Replacement
NOTE
New sight gauge does not come with the float ball installed. You can retain the old float ball from the
defective sight gauge for installation in the new gauge, or you can install a new float ball.
1.
Unscrew top and bottom outer bolts (figure 1, 1) to remove sight gauge (2) from bushings (8).
2.
Remove bushings (8) from vessel ports (7).
0010 00-2