NOTE
when equipment is in operation or being mobil-
There is a steel band around the canisters near
ized.
This band shall be replaced around can-
the top, to secure the canisters from movement
isters only after replacing elements.
Section II.
MOVEMENT TO A NEW WORKSITE
4-3. Dismantling For Movement
a n d 4 - 2 ).
When unit is drained, open air vent
valve (fig. 2-1 ) and vent air from filter-
T h e f i l t e r - s e p a r a t o r w i l l r e q u i r e n o d i s m a n -
t l i n g f o r m o v e m e n t . D r a i n u n i t ( f i g . 2 - 1 )
separator. Disconnect the inlet and outlet hose
(fig. 4-1).
Figure 4-2. Water drain plug.
4-4. Reinstallation After Movement
Refer to paragraph 4-2 and reinstall the filter-
separator in a similar manner.
Section III.
PREVENTIVE MAINTENANCE CHECKS AND SERVICES
To insure that the filter-separator is ready for
listed in table 4-1.
T h e i t e m n u m b e r s i n d i c a t e
-
operation at all times, it must be inspected sys-
t h e s e q u e n c e o f m i n i m u m i n s p e c t i o n r e q u i r e-
t e m a t i c a l l y s o t h a t d e f e c t s m a y b e d i s c o v e r ed
ments.
O n l y t h o s e f a u l t s t h a t c a n n o t b e c o r-
and corrected before they result in serious dam-
rected by the Operator or Crew or that are cor-
age or failure. The necessary preventive main -
rected by replacing parts will be recorded on DA
tenance checks and services to be performed are
F o r m 2 4 0 4 .
Table 4-1. Preventive Maintenance Checks and Services.
Items to be inspected
M
Q
Procedure
1
SIGHT GAGE
I n s p e c t f o r c r a c k e d s i g h t g a g e a n d b a l l f l o a t f o r d a m a g e . R e p l a c e i f d a m a g e d .
2
FILTER SEPARATOR
I n s p e c t f i l t e r - s e p a r a t o r f o r d a m a g e t o b o d y o r e x t e r n a l c o m p o n e n t s . R e p l a c e
damaged components.
4-2