2-25. CABLE C5-19-6160-40 - MAINTENANCE INSTRUCTIONS.
This task covers:
c. Replace
a. Removal
d. Installation
b. Test
Test Equipment
Multimeter AN/USM223
ACTION
ITEM
LOCATION
WARNING
Before removing any cable, be sure that POWER switch on compartment control module is in the OFF
position and that the collective protection equipment power source is shut down.
Set compartment control module POWER switch (1)
Cable C5-19-6160-40
Power Distribution Unit
to OFF.
and Feed-Thru*
Connector
Shut down collective protection equipment
power source.
Disconnect cable assembly plug P1 (2) from feed-thru*
connector J1 (3).
Disconnect cable assembly plug P3 (4) from power
distribution unit connector J3 (5).