Remove combustion return line (8) and nozzle valve line (9) and pull from
nonmetallic grommets (10 and 11).
Nozzle valve line (9)
Nonmetallic grommet (10)
Nonmetallic grommet (11)
Remove nozzle holder assembly (12) and combustor plate (13) only if
Nozzle holder assembly (12)
damaged.
Combustor plate (13)
Remove cover panel from pressure switch (14). Disconnect electrical
Pressure switch (14)
wiring from pressure switch (14). Unscrew and remove pressure
switch (14).
TM 3-4230-209-20&P
2-209