SKID BASE ASSEMBLY. - Continued
SKID BASE ASSEMBLY. - Continued

Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  214    215    216    217    218  219  220    221    222    223    224  
img
Skid Base Assembly/
Repair by replacing authorized items.
Authorized items
Skid Base Assembly/
Direct current motor (1)
Position direct current motor (1) into skid base (2), and secure with four
internal tooth lock washers (3) and hexagon head cap screws (4). Re-
Skid base (2)
attach electrical lead (5).
Internal tooth lock
washers (3)
Hexagon head cap
screws (4)
Electrical lead (5)
Install the two drive arms (6) and aline hole. Secure with the spring
Drive arms (6)
pins (7).
Spring pins (7)
Install magneto assembly (8) onto end of direct current motor (1) and aline
Magneto assembly (8)
mounting holes. Secure with four internal tooth lock washers (9) and
Internal tooth lock
hexagon head cap screws (10). Attach igniter cable assembly (11 ).
washers (9)
Hexagon head cap
screws (10)
Igniter cable assembly (11 )