LIQUID FUEL WATER HEATER - Continued
LIQUID FUEL WATER HEATER - Continued

Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  158    159    160    161    162  163  164    165    166    167    168  
img
Carefully tag before disconnecting wires.
Unscrew and remove hexagon Plain nut (36) and internal tooth lock
Hexagon plain nut (36)
washer (37) from ground lug (38). Lift white wire of power cable
Internal tooth lock
assembly (39) from ground lug. Reinstall lock washer (37) and hexagon
washer (37)
plain nut (36) on ground lug (38).
Ground lug (38)
Power cable assembly (39)
Locate K1 relay (40). Unscrew and remove nut (41) and washer (42) from
K1 relay (40)
terminal identified as A2 and liftoff black wire of power cable
Nut (41)
assembly (39) and wire identified as 16. Reattach washer (42) and
Washer (42)
nut (41).
TM 3-4230-209-20&P