CONTROL PANEL ASSEMBLY.
CONTROL PANEL ASSEMBLY. - Continued

Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  123    124    125    126    127  128  129    130    131    132    133  
img
2-106
TM 3-4230-209-20&P
2-26. CONTROL PANEL ASSEMBLY CONT).
LOCATION/lTEM
ACTION
REMARKS
Control Panel Assembly/
Electrical leads (12)
Disconnect electrical leads (12) from pressure indicator (13).
Carefully tag and disconnect electrical leads (12 and
Pressure indicator (13)
16) for reassembly.
Remove nuts (14) and bracket (15) from rear of control panel (3). Remove
Nuts (14)
Bracket (15)
pressure indicator (13) from front of control panel (3).
Electrical leads (16)
Disconnect electrical leads (16) from liquid quantity indicator (17).
Liquid quantity
indicator (17)
Nuts (18)
Remove nuts (18) and bracket (19) from rear of control panel. Remove
Bracket (19)
liquid quantity indicator (17) from front of control panel (3).