TROUBLESHOOTING PROCEDURES - Continued
TROUBLESHOOTING PROCEDURES - Continued

Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  44    45    46    47    48  49  50    51    52    53    54  
img
c. Check for 24 vdc between HEATER ON/PURGE ON switch (S4), terminals 1, 2, and 5, and ground.
(1) If voltage is indicated at terminal 2 but not at 1 or 5, replace switch.
(2) If voltage is indicated at terminals 2 and 1 but not 5, notify intermediate direct support maintenance to
repair jumper wire.
(3) If no voltage is indicated at 1, 2, and 5, disconnect wires from flame switch (S2) (6) and measure
across contacts for continuity. If infinity is indicated, replace S2 switch.
TM 3-4230-209-20&P
2-27