DECONTAMINATING APPARATUS, ABC-M11 - Continued
DECONTAMINATING APPARATUS, ABC-M11 - Continued

Maintenance Manual For Decontaminating Apparatus, Portable, Ds2, 1-1/2 Quart, Abc-M11
Page Navigation
  24    25    26    27    28  29  30    31    32    33    34  
img
TM 3-4230-204-12&P
8
7
a. Using primer coat and forest green enamel, paint the screws and
a. Move the bracket (6) top edge left or right until it is vertical.
nuts to cover any shiny surfaces.
b. Use upper hole in bracket as a guide. Center punch and drill the
NOTE
second hole.  Install a hexagon head cap screw (3) through the
Be sure to put the nitrogen cylinder in the bracket
bracket (6) and through the surface. From the backside of mounting
before mounting your M11 DECON.
surface install second lock washer (4) and hexagon plain nut (5).
Tighten.
b. Position the M11 DECON (2) onto the bracket (6). Fasten strap
around the M11 DECON and latch.
c. Install the third screw (3), lockwasher (4), and nut (5). Tighten.
4-11