TM 10-4330-236-13&P
2-4. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - continued.
Table 2-1. Operator Preventive Maintenance Checks and Services for 200 GPM Filter-Separator.
Location
Item
Item to
Not Fully Mission
No
Interval
Check/Service
Procedures
Capable If:
9
Before
Ground Cable
Inspect ground cable for damage, loose,
Cable not secure.
or missing hardware.
Hardware is loose, damaged,
or missing.
10
Before
Ground Rod
Inspect for loose, damaged or missing
Ground rod loose, damaged
ground rod.
or missing.
11
Before
Swivel Caster
a. Inspect for bent mounting parts,
Wheel Assembly
binding bearings or swivel.
b. Inspect tire for inflation or
damage.
12
Before
Defrost Door
Inspect for damaged or missing door.
13
Before
Adapter Assembly,
a. Inspect for loose, damaged, or
Sample probe loose.
Water Detection
missing sampling probe.
damaged, or missing.
b. Inspect coupling for cracks or
Coupling cracked or
damage.
damaged.
c. Inspect for missing or damaged
Gasket missing or damaged.
gasket
14
Before
Fuel Outlet
a. Inspect coupling for cracks or breaks.
Coupling cracked or broken.
Coupling
b. Inspect for missing or damaged cap,
Gasket damaged or missing.
chain or gasket.
15
Before
Water Drain
a. Inspect for loose or damaged fittings.
Fittings loose or damaged.
Piping
b. Inspect for loose, damaged, or
missing hose
16
Before
Water Drain Valve
a. Inspect for loose or missing handle.
Handle does not rotate
Rotate handle, should turn 90°
freely.
freely.
Hardware missing.
Valve sticks.
b. Inspect valve body for cracks.
Body cracked.
2-7