4-22.
Grounding Rod Assembly (cont).
b.
Replace. (figure 4-18)
(1)
Remove screw (1) and locknut (2) securing clamp (3) and remove.
(2)
Remove grounding rods (4) from frame (5).
(3)
Position grounding rods (4) on frame (5).
(4)
Install clamp (3) and secure with screw (1) and nut (2).