TM 5-4330-217-12
C7
Page 1-5. Paragraph 1-6 is superseded as follows:
1-6. Differences in Models. The differences in models are that the Model 844-5-V-100AL has a pop-up type
differential pressure indicator and ModeIs V-1520-ANZ and FS-100VM have a differential pressure indicating gage.
Page 1-5. Paragraph 1-7b (1.2) is added as follows:
(1.2)
Identification.
Beta Systems, Inc.
Manufacturer . . . . . . . . . . . .
.
FS-100VM
Model Number . . . . . . . . . .
.
4330-00-491-4957
Federal Stock No. . . . . . . . .
.
DAAK01-93-C-0106
Contract No . . . . . . . . . . . . .
.
52556C
Specification No. . . . . . . . . .
.
Page 1-5. Paragraph 1-7b (5.1). Change heading to read:
(5.1) Differential pressure indicator (Models V-1520-ANZ and FS-100VM).
Page 2-1. Paragraph 2-2b (5) is superseded as follows:
(5) Check differential indicator periodically. Change filter elements (para 3-5) immediately if the red button
on the indicator is in a raised position (Model 844-5-V-100AL) or the gage readings are in any portion of the red
band (Models V-1520-ANZ and FS-100VM).
Page 2-2. Paragraph 2-4a (3), add as follows:
(3) For Model V-1520-ANZ and FS-100VM filter-separators, check the pressure differential gage
periodically to be sure the pressure reading is below the red band on the gage.
Page 2-2. Paragraph 2-4b (5), add as follows:
(5) For Model V-1520-ANZ and FS-100VM filter-separators, check the pressure differential gage
periodically to be sure the pressure reading is below the red band on the gage.
Page 2-2. Paragraph 2-4c (4), add as follows:
(4) For Model V-1520-ANZ and FS-100VM filter-separators, check the pressure differential gage
periodically to be sure the pressure reading is below the red band on the gage.
Page 2-2. Paragraph 2-4d (3), add as follows:
(3) For Model V-1520-ANZ and FS-100VM filter-separators, check the pressure differential gage
periodically to be sure the pressure reading is below the red band on the gage.
Page 2-2. Paragraph 2-4e (3), add as follows:
(3) For Model V-1520-ANZ and FS-100VM filter-separators, check the pressure differential gage
periodically to be sure the pressure reading is below the red band on the gage.
Page 4-5. Table 4-2, Item 1, "Malfunction" column add:
"YELLOW BAND READING ON DIFFERENTIAL PRESSURE GAGE (MODELS V-1520-ANZ AND FS-100VM)."
4
Change 7