TM 3-4240-284-20&P
ACTION
ITEM
LOCATION
REPLACE/REPAIR
.
TACPIRE
Airduct hoses
Replace if not repairable.
Repair:
Clean damaged areas using rags (item 6, app D) and
dry-cleaning solvent (item 4, app D).
Cut a piece of tape (item 7, app D) 4 inches longer
than the slit or tear.
Apply the tape over the damaged area leaving 2
inches of tape beyond the tear or slit at each end.
Press tape firmly in place.
INSTALLATION
Push each end of airduct hose (2) over adapters
Airduct hoses
TACFIRE
(3 and 4).
Check that edge of hose is pushed against the bead on
the adapter.
Tighten hose damp adjusting screws (1) securely.
2-109(2-110 Blank)