CABLE C5-19-6170-40 - MAINTENANCE INSTRUCTIONS. - Continued
CABLE CS-19-6162-10 - MAINTENANCE INSTRUCTIONS. - Continued

Collective Protection Equipment, Fire Direction System, Artillery, \(Tacfire\) An/Gsg-10\(V\), M262
Page Navigation
  101    102    103    104    105  106  107    108    109    110    111  
img
TM 3-4240-284-20&P
2-22. CABLE CS-19-6162-10 - MAINTENANCE INSTRUCTIONS.
This task covers:
c. Installation
b. Test
a. Removal
INITIAL SETUP
Test Equipment
Multimeter AN/USM223
LOCATION
ACTION
ITEM
REMOVAL
Set compartment control module POWER switch (1)
M10 Protective Entrance
CabIe C5-19-6162-10
to OFF.
and Power Distribution Unit
Shut down collective protection equipment
power source.
Disconnect electrical cable plug P20 (2) from protective
entrance enclosure connector J20 (3).
Disconnect electrical cable plug P5 (4) from power
distribution unit connector J5 (5).