2-22. CABLE CS-19-6162-10 - MAINTENANCE INSTRUCTIONS.
This task covers:
c. Installation
b. Test
a. Removal
INITIAL SETUP
Test Equipment
LOCATION
ACTION
ITEM
REMOVAL
Set compartment control module POWER switch (1)
M10 Protective Entrance
CabIe C5-19-6162-10
to OFF.
and Power Distribution Unit
Shut down collective protection equipment
power source.
Disconnect electrical cable plug P20 (2) from protective
entrance enclosure connector J20 (3).
Disconnect electrical cable plug P5 (4) from power
distribution unit connector J5 (5).