FUNCTION TEST - Continued
MASK LIGHT FLASHING AND/OR WARNING HORN SOUNDING.

Collective Protection Equipment, Fire Direction System, Artillery, \(Tacfire\) An/Gsg-10\(V\), M262
Page Navigation
  14    15    16    17    18  19  20    21    22    23    24  
img
. . . . . . . . .
TM 3-4240-284-20&P
Section V. TROUBLESHOOTING
2-8. GENERAL.
b. This manual cannot list all possible malfunc-
tions that may occur, nor all tests or inspec-
a. This section contains troubleshooting infor-
tions and corrective actions. If a malfunction
mation for locating and correcting most of
is not listed (except when malfunction and
the operating troubles which may develop in
cause are obvious) or is not corrected by
your protective equipment. Each malfunc-
listed corrective actions, notify your super-
tion for an individual component, unit, or
visor.
system is followed by a list of tests or inspec-
tions which will help you to determine cor-
NOTE
rective actions to take. You should perform
When measuring voltage at the Power
the test/inspections and corrective actions in
Distribution Unit (PDU), TP #10 is
the order listed.
ground. PDU is actually installed on its
.
side, but is shown rightside up for clarity.
2-9. TROUBLESHOOTING PROCEDURES.
a. Perform functional test first. Then use the
s y m p t o m index for quick access to the
troubleshooting procedures.
Troubleshooting
SYMPTOM INDEX
Procedure
Page
1.
MASK light flashing and/or warning horn sounding . . . . . . . . . . . . . . . . . . . . . ..2-l2
2.
Protective entrance LOW PRESSURE lights on . . . . . . . . . . . . . . . . . . . . . . . 2-22
3.
No power indication (all indicator lights do not illuminate
w h e n p r e s s e d t o t e s t.). . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..... . . . . . . . . . . 2-33
...
4.
Protective entrance LOW PRESSURE lights will not come on . . . . . . . . . . ...2-39
5.
CHANGE FILTER lights with clean filter . . .... . . . . . . . . . . . . . . . . . . . . . . . 2-45
6.
CHANGE FILTER light does not illuminate .. . . . . . . . . . . . . . . 2-46
7.
OCCUPIED AND PURGE lights do not operate properly . . . . . . . . . . . . . . ...2-48
8.
INDICATORS circuit breaker trips . . . . ..... . . . . . . . . . . . . . . . . . . . 2-51
9.
Protective Entrance dome light does not come on . . . . . . . . . . . . . . . . . . . . . . . ..2-54